Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anal Chem ; 96(11): 4455-4462, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38458998

RESUMO

The functions of proteins bearing multiple post-translational modifications (PTMs) are modulated by their modification patterns, yet precise characterization of them is difficult. MEK1 (also known as MAP2K1) is one such example that acts as a gatekeeper of the mitogen-activating protein kinase (MAPK) pathway and propagates signals via phosphorylation by upstream kinases. In principle, top-down mass spectrometry can precisely characterize whole MEK1 proteoforms, but fragmentation methods that would enable the site-specific characterization of labile modifications on 43 kDa protein ions result in overly dense tandem mass spectra. By using the charge-detection method called individual ion mass spectrometry, we demonstrate how complex mixtures of phosphoproteoforms and their fragment ions can be reproducibly handled to provide a "bird's eye" view of signaling activity through mapping proteoform landscapes in a pathway. Using this approach, the overall stoichiometry and distribution of 0-4 phosphorylations on MEK1 was determined in a cellular model of drug-resistant metastatic melanoma. This approach can be generalized to other multiply modified proteoforms, for which PTM combinations are key to their function and drug action.


Assuntos
Mitógenos , Proteínas Quinases , Espectrometria de Massas em Tandem/métodos , Processamento de Proteína Pós-Traducional , Peptídeos e Proteínas de Sinalização Intercelular , Íons
3.
J Am Soc Mass Spectrom ; 34(12): 2625-2629, 2023 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-38011219

RESUMO

Collision cross section (CCS) measurements determined by ion mobility spectrometry (IMS) provide useful information about gas-phase protein structure that is complementary to mass analysis. Methods for determining CCS without a dedicated IMS system have been developed for Fourier transform mass spectrometry (FT-MS) platforms by measuring the signal decay during detection. Individual ion mass spectrometry (I2MS) provides charge detection and measures ion lifetimes across the length of an FT-MS detection event. By tracking lifetimes for entire ion populations, we demonstrate simultaneous determination of charge, mass, and CCS for proteins and complexes ranging from ∼8 to ∼232 kDa.


Assuntos
Espectrometria de Mobilidade Iônica , Proteínas , Espectrometria de Massas/métodos , Proteínas/química , Espectrometria de Mobilidade Iônica/métodos
4.
Nat Commun ; 14(1): 6478, 2023 10 14.
Artigo em Inglês | MEDLINE | ID: mdl-37838706

RESUMO

The molecular identification of tissue proteoforms by top-down mass spectrometry (TDMS) is significantly limited by throughput and dynamic range. We introduce AutoPiMS, a single-ion MS based multiplexed workflow for top-down tandem MS (MS2) directly from tissue microenvironments in a semi-automated manner. AutoPiMS directly off human ovarian cancer sections allowed for MS2 identification of 73 proteoforms up to 54 kDa at a rate of <1 min per proteoform. AutoPiMS is directly interfaced with multifaceted proteoform imaging MS data modalities for the identification of proteoform signatures in tumor and stromal regions in ovarian cancer biopsies. From a total of ~1000 proteoforms detected by region-of-interest label-free quantitation, we discover 303 differential proteoforms in stroma versus tumor from the same patient. 14 of the top proteoform signatures are corroborated by MSI at 20 micron resolution including the differential localization of methylated forms of CRIP1, indicating the importance of proteoform-enabled spatial biology in ovarian cancer.


Assuntos
Neoplasias Ovarianas , Proteoma , Humanos , Feminino , Proteoma/análise , Neoplasias Ovarianas/diagnóstico por imagem , Espectrometria de Massas em Tandem/métodos , Software , Microambiente Tumoral
5.
J Am Soc Mass Spectrom ; 34(10): 2093-2097, 2023 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-37683262

RESUMO

Antibody-antigen interactions are central to the immune response. Variation of protein antigens such as isoforms and post-translational modifications can alter their antibody binding sites. To directly connect the recognition of protein antigens with their molecular composition, we probed antibody-antigen complexes by using native tandem mass spectrometry. Specifically, we characterized the prominent peanut allergen Ara h 2 and a convergent IgE variable region discovered in patients who are allergic to peanuts. In addition to measuring the antigen-induced dimerization of IgE antibodies, we demonstrated how immunocomplexes can be isolated in the gas phase and activated to eject, identify, and characterize proteoforms of their bound antigens. Using tandem experiments, we isolated the ejected antigens and then fragmented them to identify their chemical composition. These results establish native top-down mass spectrometry as a viable platform for precise and thorough characterization of immunocomplexes to relate structure to function and enable the discovery of antigen proteoforms and their binding sites.


Assuntos
Alérgenos , Espectrometria de Massas em Tandem , Humanos , Isoformas de Proteínas , Imunoglobulina E/metabolismo , Antígenos de Plantas/metabolismo
6.
Anal Chem ; 94(48): 16543-16548, 2022 12 06.
Artigo em Inglês | MEDLINE | ID: mdl-36416365

RESUMO

Charge detection mass spectrometry (CDMS) provides mass domain spectra of large and highly heterogeneous analytes. Over the past few years, we have multiplexed CDMS on Orbitrap instruments, an approach termed Individual Ion Mass Spectrometry (I2MS). Until now, I2MS required manual adjustment of injection times to collect spectra in the individual ion regime. To increase sample adaptability, enable online separations, and reduce the barrier for entry, we report an automated method for adjusting ion injection times in I2MS for image current detectors like the Orbitrap. Automatic Ion Control (AIC) utilizes the density of signals in the m/z domain to adjust an ensemble of ions down to the individual ion regime in real-time. The AIC technique was applied to both denatured and native proteins yielding high quality data without human intervention directly in the mass domain.


Assuntos
Proteínas , Humanos , Espectrometria de Massas/métodos , Íons/química , Proteínas/análise
7.
Sci Adv ; 8(32): eabp9929, 2022 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-35947651

RESUMO

Imaging of proteoforms in human tissues is hindered by low molecular specificity and limited proteome coverage. Here, we introduce proteoform imaging mass spectrometry (PiMS), which increases the size limit for proteoform detection and identification by fourfold compared to reported methods and reveals tissue localization of proteoforms at <80-µm spatial resolution. PiMS advances proteoform imaging by combining ambient nanospray desorption electrospray ionization with ion detection using individual ion mass spectrometry. We demonstrate highly multiplexed proteoform imaging of human kidney, annotating 169 of 400 proteoforms of <70 kDa using top-down MS and a database lookup of ~1000 kidney candidate proteoforms, including dozens of key enzymes in primary metabolism. PiMS images reveal distinct spatial localizations of proteoforms to both anatomical structures and cellular neighborhoods in the vasculature, medulla, and cortex regions of the human kidney. The benefits of PiMS are poised to increase proteome coverage for label-free protein imaging of tissues.

8.
Acc Chem Res ; 55(14): 1928-1937, 2022 07 19.
Artigo em Inglês | MEDLINE | ID: mdl-35749283

RESUMO

Biology is driven by a vast set of molecular interactions that evolved over billions of years. Just as covalent modifications like acetylations and phosphorylations can change a protein's function, so too can noncovalent interactions with metals, small molecules, and other proteins. However, much of the language of protein-level biology is left either undiscovered or inferred, as traditional methods used in the field of proteomics use conditions that dissociate noncovalent interactions and denature proteins.Just in the past few years, mass spectrometry (MS) has evolved the capacity to preserve and subsequently characterize the complete composition of endogenous protein complexes. Using this "native" type of mass spectrometry, a complex can be activated to liberate some or all of its subunits, typically via collisions with neutral gas or solid surfaces and isolated before further characterization ("Native Top-Down MS," or nTDMS). The subunit mass, the parent ion mass, and the fragment ions of the activated subunits can be used to piece together the precise molecular composition of the parent complex. When performed en masse in discovery mode (i.e., "native proteomics"), the interactions of life─including protein modifications─will eventually be clarified and linked to dysfunction in human disease states.In this Account, we describe the current and future components of the native MS toolkit, covering the challenges the field faces to characterize ever larger bioassemblies. Each of the three pillars of native proteomics are addressed: (i) separations, (ii) top-down mass spectrometry, and (iii) integration with structural biology. Complexes such as endogenous nucleosomes can be targeted now using nTDMS, whereas virus particles, exosomes, and high-density lipoprotein particles will be tackled in the coming few years. The future work to adequately address the size and complexity of mega- to gigadalton complexes will include native separations, single ion mass spectrometry, and new data types. The use of nTDMS in discovery mode will incorporate native-compatible separation techniques to maximize the number of proteoforms in complexes identified. With a new wave of innovations, both targeted and discovery mode nTDMS will expand to include extremely scarce and exceedingly heterogeneous bioassemblies. Understanding the proteinaceous interactions of life and how they go wrong (e.g., misfolding, forming complexes in dysfunctional stoichiometries and configurations) will not only inform the development of life-restoring therapeutics but also deepen our understanding of life at the molecular level.


Assuntos
Proteínas , Proteômica , Humanos , Íons , Espectrometria de Massas/métodos , Proteínas/química , Proteômica/métodos
9.
J Proteome Res ; 21(1): 274-288, 2022 01 07.
Artigo em Inglês | MEDLINE | ID: mdl-34878788

RESUMO

Methods of antibody detection are used to assess exposure or immunity to a pathogen. Here, we present Ig-MS, a novel serological readout that captures the immunoglobulin (Ig) repertoire at molecular resolution, including entire variable regions in Ig light and heavy chains. Ig-MS uses recent advances in protein mass spectrometry (MS) for multiparametric readout of antibodies, with new metrics like Ion Titer (IT) and Degree of Clonality (DoC) capturing the heterogeneity and relative abundance of individual clones without sequencing of B cells. We applied Ig-MS to plasma from subjects with severe and mild COVID-19 and immunized subjects after two vaccine doses, using the receptor-binding domain (RBD) of the spike protein of SARS-CoV-2 as the bait for antibody capture. Importantly, we report a new data type for human serology, that could use other antigens of interest to gauge immune responses to vaccination, pathogens, or autoimmune disorders.


Assuntos
COVID-19 , SARS-CoV-2 , Anticorpos Neutralizantes , Anticorpos Antivirais , Humanos , Espectrometria de Massas , Glicoproteína da Espícula de Coronavírus/genética
10.
Int J Mass Spectrom ; 4652021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34539228

RESUMO

The combined use of electrospray ionization run in so-called "native mode" with top-down mass spectrometry (nTDMS) is enhancing both structural biology and discovery proteomics by providing three levels of information in a single experiment: the intact mass of a protein or complex, the masses of its subunits and non-covalent cofactors, and fragment ion masses from direct dissociation of subunits that capture the primary sequence and combinations of diverse post-translational modifications (PTMs). While intact mass data are readily deconvoluted using well-known software options, the analysis of fragmentation data that result from a tandem MS experiment - essential for proteoform characterization - is not yet standardized. In this tutorial, we offer a decision-tree for the analysis of nTDMS experiments on protein complexes and diverse bioassemblies. We include an overview of strategies to navigate this type of analysis, provide example data sets, and highlight software for the hypothesis-driven interrogation of fragment ions for localization of PTMs, metals, and cofactors on native proteoforms. Throughout we have emphasized the key features (deconvolution, search mode, validation, other) that the reader can consider when deciding upon their specific experimental and data processing design using both open-access and commercial software.

11.
medRxiv ; 2021 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-34268518

RESUMO

Methods of antibody detection are used to assess exposure or immunity to a pathogen. Here, we present Ig-MS , a novel serological readout that captures the immunoglobulin (Ig) repertoire at molecular resolution, including entire variable regions in Ig light and heavy chains. Ig-MS uses recent advances in protein mass spectrometry (MS) for multi-parametric readout of antibodies, with new metrics like Ion Titer (IT) and Degree of Clonality (DoC) capturing the heterogeneity and relative abundance of individual clones without sequencing of B cells. We apply Ig-MS to plasma from subjects with severe & mild COVID-19, using the receptor-binding domain (RBD) of the spike protein of SARS-CoV-2 as the bait for antibody capture. Importantly, we report a new data type for human serology, with compatibility to any recombinant antigen to gauge our immune responses to vaccination, pathogens, or autoimmune disorders.

12.
Anal Chem ; 93(16): 6323-6328, 2021 04 27.
Artigo em Inglês | MEDLINE | ID: mdl-33844503

RESUMO

Field asymmetric ion mobility spectrometry (FAIMS), when used in proteomics studies, provides superior selectivity and enables more proteins to be identified by providing additional gas-phase separation. Here, we tested the performance of cylindrical FAIMS for the identification and characterization of proteoforms by top-down mass spectrometry of heterogeneous protein mixtures. Combining FAIMS with chromatographic separation resulted in a 62% increase in protein identifications, an 8% increase in proteoform identifications, and an improvement in proteoform identification compared to samples analyzed without FAIMS. In addition, utilization of FAIMS resulted in the identification of proteins encoded by lower-abundance mRNA transcripts. These improvements were attributable, in part, to improved signal-to-noise for proteoforms with similar retention times. Additionally, our results show that the optimal compensation voltage of any given proteoform was correlated with the molecular weight of the analyte. Collectively these results suggest that the addition of FAIMS can enhance top-down proteomics in both discovery and targeted applications.


Assuntos
Espectrometria de Mobilidade Iônica , Proteômica , Espectrometria de Massas , Proteínas
13.
Electrophoresis ; 42(9-10): 1050-1059, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33502026

RESUMO

Native mass spectrometry (nMS) is a rapidly growing method for the characterization of large proteins and protein complexes, preserving "native" non-covalent inter- and intramolecular interactions. Direct infusion of purified analytes into a mass spectrometer represents the standard approach for conducting nMS experiments. Alternatively, CZE can be performed under native conditions, providing high separation performance while consuming trace amounts of sample material. Here, we provide standard operating procedures for acquiring high-quality data using CZE in native mode coupled online to various Orbitrap mass spectrometers via a commercial sheathless interface, covering a wide range of analytes from 30-800 kDa. Using a standard protein mix, the influence of various CZE method parameters were evaluated, such as BGE/conductive liquid composition and separation voltage. Additionally, a universal approach for the optimization of fragmentation settings in the context of protein subunit and metalloenzyme characterization is discussed in detail for model analytes. A short section is dedicated to troubleshooting of the nCZE-MS setup. This study is aimed to help normalize nCZE-MS practices to enhance the CE community and provide a resource for the production of reproducible and high-quality data.


Assuntos
Espectrometria de Massas , Eletroforese Capilar , Proteínas , Espectrometria de Massas por Ionização por Electrospray
14.
Clin Chem Lab Med ; 59(4): 653-661, 2021 03 26.
Artigo em Inglês | MEDLINE | ID: mdl-33079696

RESUMO

OBJECTIVES: Multiple myeloma (MM) is a malignant plasma cell neoplasm, requiring the integration of clinical examination, laboratory and radiological investigations for diagnosis. Detection and isotypic identification of the monoclonal protein(s) and measurement of other relevant biomarkers in serum and urine are pivotal analyses. However, occasionally this approach fails to characterize complex protein signatures. Here we describe the development and application of next generation mass spectrometry (MS) techniques, and a novel adaptation of immunofixation, to interrogate non-canonical monoclonal immunoproteins. METHODS: Immunoprecipitation immunofixation (IP-IFE) was performed on a Sebia Hydrasys Scan2. Middle-down de novo sequencing and native MS were performed with multiple instruments (21T FT-ICR, Q Exactive HF, Orbitrap Fusion Lumos, and Orbitrap Eclipse). Post-acquisition data analysis was performed using Xcalibur Qual Browser, ProSight Lite, and TDValidator. RESULTS: We adapted a novel variation of immunofixation electrophoresis (IFE) with an antibody-specific immunosubtraction step, providing insight into the clonal signature of gamma-zone monoclonal immunoglobulin (M-protein) species. We developed and applied advanced mass spectrometric techniques such as middle-down de novo sequencing to attain in-depth characterization of the primary sequence of an M-protein. Quaternary structures of M-proteins were elucidated by native MS, revealing a previously unprecedented non-covalently associated hetero-tetrameric immunoglobulin. CONCLUSIONS: Next generation proteomic solutions offer great potential for characterizing complex protein structures and may eventually replace current electrophoretic approaches for the identification and quantification of M-proteins. They can also contribute to greater understanding of MM pathogenesis, enabling classification of patients into new subtypes, improved risk stratification and the potential to inform decisions on future personalized treatment modalities.


Assuntos
Mieloma Múltiplo , Proteínas do Mieloma , Proteômica/métodos , Anticorpos Monoclonais , Humanos , Imunoeletroforese , Espectrometria de Massas , Mieloma Múltiplo/diagnóstico
15.
Anal Chem ; 93(5): 2723-2727, 2021 02 09.
Artigo em Inglês | MEDLINE | ID: mdl-33322893

RESUMO

Native mass spectrometry involves transferring large biomolecular complexes into the gas phase, enabling the characterization of their composition and stoichiometry. However, the overlap in distributions created by residual solvation, ionic adducts, and post-translational modifications creates a high degree of complexity that typically goes unresolved at masses above ∼150 kDa. Therefore, native mass spectrometry would greatly benefit from higher resolution approaches for intact proteins and their complexes. By recording mass spectra of individual ions via charge detection mass spectrometry, we report isotopic resolution for pyruvate kinase (232 kDa) and ß-galactosidase (466 kDa), extending the limits of isotopic resolution for high mass and high m/z by >2.5-fold and >1.6-fold, respectively.


Assuntos
Processamento de Proteína Pós-Traducional , Proteínas , Íons , Espectrometria de Massas
16.
J Am Soc Mass Spectrom ; 31(3): 763-767, 2020 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-32126774

RESUMO

Intact protein mass spectrometry (MS) via electrospray-based methods is often degraded by low-mass contaminants, which can suppress the spectral quality of the analyte of interest via space-charge effects. Consequently, selective removal of contaminants by their mobilities would benefit native MS if achieved without additional hardware and before the mass analyzer regions used for selection, analyte readout, or tandem MS. Here, we use the high-pressure multipole within the source of an Orbitrap Tribrid as the foundation for a coarse ion filter. Using this method, we show complete filtration of 2 mM polyethylene glycol (PEG-1000) during native MS of SILu mAb antibody present at a 200× lower concentration. We also show the generality of the process by rescuing 10 µM tetrameric pyruvate kinase from 2 mM PEG-1000, asserting this voltage rollercoaster filtering (VRF) method for use in native MS as an efficient alternative to conventional purification methods.


Assuntos
Filtração/instrumentação , Polietilenoglicóis/isolamento & purificação , Proteínas/química , Animais , Anticorpos Monoclonais/química , Desenho de Equipamento , Humanos , Espectrometria de Massas/instrumentação , Piruvato Quinase/química
17.
MAbs ; 11(8): 1351-1357, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31607219

RESUMO

The analysis of monoclonal antibodies (mAbs) by a middle-down mass spectrometry (MS) approach is a growing field that attracts the attention of many researchers and biopharmaceutical companies. Usually, liquid fractionation techniques are used to separate mAbs polypeptides chains before MS analysis. Gas-phase fractionation techniques such as high-field asymmetric waveform ion mobility spectrometry (FAIMS) can replace liquid-based separations and reduce both analysis time and cost. Here, we present a rapid FAIMS tandem MS method capable of characterizing the polypeptide sequence of mAbs light and heavy chains in an unprecedented, easy, and fast fashion. This new method uses commercially available instruments and takes ~24 min, which is 40-60% faster than regular liquid chromatography-MS/MS analysis, to acquire fragmentation data using different dissociation methods.


Assuntos
Anticorpos Monoclonais/química , Cadeias Pesadas de Imunoglobulinas/química , Cadeias Leves de Imunoglobulina/química , Espectrometria de Massas por Ionização por Electrospray , Espectrometria de Massas em Tandem , Cromatografia Líquida
18.
J Am Soc Mass Spectrom ; 30(7): 1190-1198, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30963455

RESUMO

Native mass spectrometry (nMS) is a technique growing at the interface of analytical chemistry, structural biology, and proteomics that enables the detection and partial characterization of non-covalent protein assemblies. Currently, the standardization and dissemination of nMS is hampered by technical challenges associated with instrument operation, benchmarking, and optimization over time. Here, we provide a standard operating procedure for acquiring high-quality native mass spectra of 30-300 kDa proteins using an Orbitrap mass spectrometer. By describing reproducible sample preparation, loading, ionization, and nMS analysis, we forward two proteoforms and three complexes as possible standards to advance training and longitudinal assessment of instrument performance. Spectral data for five standards can guide assessment of instrument parameters, data production, and data analysis. By introducing this set of standards and protocols, we aim to help normalize native mass spectrometry practices across labs and provide benchmarks for reproducibility and high-quality data production in the years ahead. Graphical abstract.


Assuntos
Espectrometria de Massas/métodos , Multimerização Proteica , Proteínas/química , Álcool Desidrogenase/química , Animais , Anidrases Carbônicas/química , Bovinos , Modelos Moleculares , Piruvato Quinase/química , Coelhos , Reprodutibilidade dos Testes , Saccharomyces cerevisiae/química , Proteínas de Saccharomyces cerevisiae/química
19.
Spine (Phila Pa 1976) ; 35(5): E163-6, 2010 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-20147872

RESUMO

STUDY DESIGN: Case study. OBJECTIVE: To emphasize the role that interventional radiology can perform in stemming bleeding to vascular structures injured during spine surgery without altering patient position. SUMMARY AND BACKGROUND DATA: Injury to the lumbar artery or aorta may occur during lumbar disc surgery. Occasionally the site of bleeding may not be readily identifiable or accessible through the surgical incision. Interventional radiology techniques may be employed to help locate and stop these difficult to locate vascular structures without changing a patient position. METHODS: A 48-year-old woman undergoing L4-L5 lumbar hemilaminectomy and discectomy secondary to a herniated disc sustained an injury to a right L3 lumbar artery. Several liters of blood were lost in an attempt to surgically locate and repair the injury to the lumbar artery. A literature search identified the potential severity and treatment options. RESULTS: An interventional radiologist was called for and he was able to angiographically locate the source of bleeding and stem its source using coil embolization of the lumbar artery. CONCLUSION: Whenever there is bleeding from an inaccessible site, consultation with an interventional radiologist to perform an intraoperative coil embolization of the injured vessel should be done especially if a resort to an anterior abdominal approach would permit uncontrolled bleeding.


Assuntos
Perda Sanguínea Cirúrgica , Discotomia/efeitos adversos , Embolização Terapêutica/métodos , Deslocamento do Disco Intervertebral/cirurgia , Laminectomia/efeitos adversos , Medula Espinal/irrigação sanguínea , Feminino , Humanos , Deslocamento do Disco Intervertebral/diagnóstico por imagem , Período Intraoperatório , Vértebras Lombares/irrigação sanguínea , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Pessoa de Meia-Idade , Radiografia , Medula Espinal/diagnóstico por imagem , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...